An Analysis Of Rc Interior Connection Through Ferrous Steel Plate Coupler

Main Article Content

A. ANBUCHEZIAN , M.VAIRAVEL

Abstract

This research's assessment process was carried out on the Ferrous steel plate coupler, which has been subjected to the interior column-joint. Almost six specimens have been selected in this process, and the joint test is done using a reversible cyclic–load segment. To showcase the efficiency of the Ferrous steel plate coupler, three types of joints have been considered. The joints used for the process are E-SMRJ, E-OMRJ, and E-FTJ. The third joint used for this process has o joint stirrups and no anchorage. This process's outcome proved that specimen one with a Ferrous steel plate coupler has more efficiency than the other specimens. The comparative study in this research is done within the requirements of national codes and the internal codes. The outcome of comparative study shows that the proposed joint specimen's code is excellent, and the prediction made on the shear strength of the joint was very close to the experimentation outcome.

Article Details

Section
Articles